13: Advanced Settings
EDS User Guide 125
CLI Configuration
On this page you can change CLI configuration settings.
Configure the CLI:
1. Click CLI on the menu then Configuration at the top of the page. The Command
Line Interface Configuration page appears.
Figure 13-4. Command Line Interface Configuration
2. Enter or modify the following settings:
Command Line
Interface
Configuration
Settings
Description
Telnet Access Select On to enable Telnet access. Telnet is enabled
by default.
Telnet Port
Enter the Telnet port to use for Telnet access. The
default is 23.
Telnet Max
Maximum number of simultaneous Telnet sessions.