Introduction
1.5 RJ-45 Serial Connector
The serial RJ-45 serial connector supports up to 115200 bits per second and has the
following signals.
Table 1 - Serial RJ45 Pinouts
Pin Direction Name Function
1 Not Connected None
2
Hard-wired output
DTR DTR Data Terminal Ready
3 To XPress DR
RXD or RXA
RS-232: RXD (Received Data)
RS-422/485:RXA (Received Data -)
4 From XPress DR TXD or TXA RS-232: TXD (Transmit Data)
RS-422/485: TXA (Transmit Data -)
5 GND Ground
6 To XPress DR CTS or RXB RS-232: CTS (Clear to Send)
RS-422/485: RXB (Received Data +)
7 From XPress DR RTS or TXB RS-232: RTS (Request to Send)
RS-422/485: TXB (Transmit Data +)
8 Not Connected None
Note: Pin 2 (DTR) is hard wired (+12V) and cannot be affected by software control.
Note: For RS-485 2-wire functionality, pins 3 & 4 and 6 & 7 must be connected together.