Configure
3.6.9 Flush Mode (Buffer Flushing)
Using this parameter, you can control line handling and network buffers with connection
startup and disconnect. You can also select between two different packing algorithms.
Note: See Table 39 - Binary to Hexadecimal Conversion Table.
Table 17 - Flush Mode Options
Function 7 6 5 4 3 2 1 0
Input Buffer (Serial to Network)
Clear with a connection that is initiated from
the UDS to the network
1
Clear with a connection initiated from the
network to the UDS
1
Clear when the network connection to or from
the UDS is disconnected
1
Output Buffer (Network to Serial)
Clear with a connection that is initiated from
the UDS to the network
1
Clear with a connection initiated from the
network to the UDS
1
Clear when the network connection to or from
the UDS is disconnected
1
Alternate Packing Algorithm (Pack Control)
Enable 1
3-22 DSTni-XPress DR User Guide