Command Reference Set/Define Port Commands
12-15
12.24 Set/Define Port Commands
12.24.1 Define Port Access
Sets the type of connections allowed to the port.
Note: Autobaud must be disabled for Remote and Dynamic ports.
Applies To EPS1, EPS2, EPS2-100, EPS4-100
Restrictions You must be the privileged user to use this command.
Errors If a port is active, its access cannot be changed.
Parameters PortList/All
Specifies a particular port or group of ports, or all ports. Port numbers are
specified with integers between 1 and the total number of physical ports. Lists
of ports must be separated by commas. Ranges of ports must be separated by
a dash (-).
Note: In the absence of a PortList or the All parameter, the configuration will affect the
current port only.
Dynamic
The port can both initiate and receive connection requests.
Local
The port may initiate connections to services, and only local logins are
permitted. This is the default.
Remote
The port can accept network connection requests but no local logins are
permitted.
None
The port is unusable.
Examples
Local> DEFINE PORT ACCESS LOCAL
See Also Show/Monitor/List Ports, page 12-63; Port Access, page 5-1.
DEFINE PORT
PortList
ALL
ACCESS
DYNAMIC
LOCAL
NONE
REMOTE






